ABB 1SAY130110R0100 K3 Connection Cable: Pre-Wired Link for 07SS91C2 DCS Modules

Description The 1SAY130110R0100​ is an ABB OEM K3-series pre-terminated connection cable, engineered to provide a reliable, noise-immune interconnection between ABB Advant OCS / Procontrol modules—most notably the 07SS91C2​ controller or I/O node—and adjacent rack-mounted devices or field termination assemblies. As a factory-tested, shielded cable assembly, it eliminates the variability of on-site point-to-point wiring in distributed control system (DCS) architectures. Application Scenarios During a controls modernisation at a 400 MW combined-cycle plant in Eastern Europe, the legacy Procontrol P13 racks were being expanded with additional 07SS91C2​ communication/I/O modules to accommodate new gas-feed skid instrumentation. The original site used hand-wired ribbon looms that had degraded over 20 years—several intermittent comms dropouts traced back to cracked insulation and poorly crimped pins. The engineering team replaced all rack-to-module links with the 1SAY130110R0100​ K3 cable. Because the cable is factory-molded with keyed OEM connectors that physically prevent reversed insertion, commissioning time for the expanded rack dropped from three shifts to one. More importantly, the shielded twin-construction suppressed the EMI from nearby 415 V MCC ducting, and the 07SS91C2​ link has run error-free for 18+ months post-retrofit. For the plant, the incremental cost of OEM cabling paid back in avoided troubleshooting hours within the first week.

Parameters

Main Parameters Value/Description
Product Model 1SAY130110R0100​ (K3 cable)
Manufacturer ABB
Product Category DCS Inter-Module Connection Cable (K3 Series)
Mating Module 07SS91C2​ (ABB Advant / Procontrol family)
Cable Type Shielded multi-conductor, PVC/LSZH outer jacket (typical)
Connector Type ABB OEM keyed rectangular (factory molded both ends)
Length Pre-defined K3 standard length (model-dependent; typically 0.5 / 1.0 / 2.0 m variants)
Conductor Gauge 24–26 AWG (signal-grade)
Shielding Overall braid + foil (EMI/RFI suppression for DCS environments)
Operating Temp. -20°C to +70°C (control-room / cabinet rating)
Compliance RoHS, ABB Advant OCS wiring spec

 

 

Technical Principles and Innovative Values

  • Innovation Point 1: Keyed OEM Molded Ends Prevent Mis-Mating.​ The 1SAY130110R0100​ uses ABB-specific polarized housings that only engage the 07SS91C2​ front-port in the correct orientation. Unlike generic ribbon or D-sub cables, there is zero risk of pin-offset wiring that could back-feed 24 VDC into a sensitive comms pin—a known failure mode in field-made cables.
  • Innovation Point 2: Double-Shielded Signal Integrity for DCS Backplanes.​ In a DCS rack, several dozen modules share the same backplane with switching digital I/O and occasional relay coils. The 1SAY130110R0100​ incorporates both foil and braided shields, drained to the rack chassis at a single point, preserving signal-to-noise ratios on the 07SS91C2​ high-speed links even when the cabinet door is open during maintenance.
  • Innovation Point 3: Plug-and-Play Commissioning with Zero Crimping.​ Every 1SAY130110R0100​ ships from ABB tested for continuity and isolation. For the end user, this means “rack it, plug it, scan it”—no wire-number cross-checking, no crimp-tool calibration logs, and no rework due to a single reversed pair.

 

 

Application Cases and Industry Value

In a Scandinavian pulp & paper mill running ABB Advant OCS across digester, bleach plant, and recovery boiler areas, the maintenance team standardized all 07SS91C2-to-adjacent-node links on the 1SAY130110R0100​ K3 cable during a 2023 reliability campaign. Previously, the site had混合 (mixed) generic D-sub cables and hand-tailored looms; MTTR on “communication loss” alarms averaged 4.2 hours because electricians had to buzzer-out each pin. Post-standardisation, the same alarm class now averages 22 minutes—technicians swap the 1SAY130110R0100​ suspect cable for a spare from the van, and the 07SS91C2​ re-synchs instantly. Over 12 months the mill logged 17 fewer unplanned downtime incidents attributed to cabling, translating to roughly €310 k in retained production.

Related Product Combination Solutions

The 1SAY130110R0100​ sits inside a broader ABB Advant / Procontrol / AC 800M ecosystem. Commonly paired items include:

 

 

  • 07SS91C2​ — The primary mating module; a communication/I/O processor in the ABB Advant family that the 1SAY130110R0100​ directly serves.
  • 07KT94​ — Advant OCS CPU module, often rack-adjacent to 07SS91C2, with K-series cables linking the two.
  • 1SBP-series terminal units — Field termination assemblies that the far end of a K3 cable may land on, depending on cabinet layout.
  • 07CR41​ / 07CR42​ — Advant remote I/O controllers, another common neighbor for K3 interlinks.
  • S800 I/O (AI810, DI810, DO820, etc.)​ — When the 07SS91C2​ bridges to S800 racks via Profibus/Fieldbus, K3 cables often handle the local rack-internal hops.
  • 1SAY130110R0101 / R0200​ — Other length/variant K3 cables in the same family, letting you scale cable runs without custom cutting.
  • ABB Advant OCS Rack (19″)​ — The backplane chassis housing 07SS91C2​ and receiving the 1SAY130110R0100​ plugs.

 

 

Installation, Maintenance, and Full-Cycle Support

Installing the 1SAY130110R0100​ requires no tools beyond the technician’s hands—align the keyed connector with the 07SS91C2​ port, press until the latch clicks, and dress the cable with the supplied nylon tie-bases along the rack DIN profile. Because the cable is pre-shaped (not a loose loom), it naturally routes through the ABB rack’s cable channel, keeping the backplane area unobstructed for future module swaps. There is no “pin 1” guesswork: the molded shell enforces polarity.

Maintenance is equally straightforward. The 1SAY130110R0100​ has no moving parts and no calibration; routine care is visual—check that the outer jacket hasn’t been nicked by a swinging cabinet door, and confirm the latch hasn’t fatigued in high-vibration skids (rare in control rooms, but possible on offshore modules). If a 07SS91C2​ reports cyclic redundancy errors (CRC) on its link, the first swap-trial is the 1SAY130110R0100—it takes under 30 seconds and either clears the fault (cable) or confirms the module needs replacement. We recommend keeping one spare K3 cable per rack type in your storeroom; the OEM part number is small enough to stock without tying up capital.

All 1SAY130110R0100​ units we supply are ABB-original or ABB-surplus verified, shipped with a basic continuity test record. Our ABB DCS specialists can cross-reference your rack BOM—send us your existing 07SS91C2​ layout and we’ll confirm the exact K3 length/variant you need (the R0100 suffix may map to a specific length; if your layout differs, we’ll suggest R0101/R0200 etc.).