HONEYWELL XNX-UTAV-RNIF1 Advanced Toxic/Combustible Gas Transmitter – 4–20 mA + Relay + HART

The HONEYWELL XNX-UTAV-RNIF1 is a universal transmitter module designed for Honeywell’s XNX fixed gas detection system, serving as the intelligent interface between gas sensors and control systems. It supports a wide range of point-type toxic, combustible, and oxygen sensors—including electrochemical, catalytic bead (pellistor), and infrared (IR)—and delivers standardized 4–20 mA output, dual programmable relays, and HART digital communication.

Engineered for hazardous industrial environments, the HONEYWELL XNX-UTAV-RNIF1 combines safety certification, diagnostic intelligence, and plug-and-play flexibility to simplify gas monitoring while enhancing personnel and asset protection.


Application Scenarios

At a North Sea offshore platform,a hydrogen sulfide(H₂S)leak during maintenance nearly caused a catastrophic incident—until the HONEYWELL XNX-UTAV-RNIF1 triggered an immediate local alarm and sent a fail-safe signal to the ESD system,shutting down non-essential equipment and activating ventilation.The unit’s dual relays were configured for“alarm”and“fault”states,allowing operators to distinguish between actual gas presence and sensor failure—preventing both dangerous delays and costly false shutdowns.This real-world response highlights how the HONEYWELL XNX-UTAV-RNIF1 turns raw sensor data into actionable safety intelligence in life-critical zones.

Parameter

Main Parameters Value/Description

Product Model HONEYWELL XNX-UTAV-RNIF1

Manufacturer Honeywell Process Solutions/Analytics

Product Category Universal Gas Detection Transmitter Module

Supported Sensor Types Electrochemical,Catalytic Bead(LEL),Infrared(IR),Oxygen(O₂)

Analog Output 4–20 mA(sink/source capable),linear or square-root

Digital Communication HART 7 over 4–20 mA loop

Relay Outputs 2 SPDT relays(5 A 250 V AC),user-configurable(alarm/fault/test)

Safety Certification SIL2(IEC 61508),ATEX,IECEx,CSA,FM

Ingress Protection IP66/NEMA 4X(when installed in XNX housing)

Operating Temperature-40°C to+70°C

Power Supply 12–30 V DC(loop-powered or external)

Display&User Interface Optional local LCD display with 4-button navigation(field-installable)

Technical Principles and Innovative Values

Innovation Point 1:True Universal Sensor Compatibility

The HONEYWELL XNX-UTAV-RNIF1 auto-detects sensor type and range via EEPROM stored in the sensor head,eliminating manual DIP switches or software reconfiguration—reducing commissioning time by up to 50%.

In创新Point 2:Dual Independent Relays with Fail-Safe Logic

Unlike basic transmitters,the HONEYWELL XNX-UTAV-RNIF1 separates“gas alarm”and“system fault”on two relays.If the sensor fails or power drops,the fault relay de-energizes predictably—enabling safe integration into SIL2 shutdown logic.

Innovation Point 3:Advanced Diagnostics&Predictive Maintenance

Built-in diagnostics monitor sensor health,baseline drift,and heater status.Data is accessible via HART or local display,enabling predictive replacement before calibration failures occur—boosting system availability.

Innovation Point 4:Seamless Integration with XNX Ecosystem

Designed as part of Honeywell’s modular XNX platform,the HONEYWELL XNX-UTAV-RNIF1 shares firmware,configuration tools(XNX Configurator),and spare parts across all XNX variants—simplifying training and inventory.

Application Cases and Industry Value

In a Middle Eastern refinery undergoing a safety upgrade,legacy gas detectors were replaced with HONEYWELL XNX-UTAV-RNIF1 transmitters across 200+points in the hydrocracker unit.The dual-relay feature allowed engineers to wire“alarm”signals to the DCS and“fault”signals directly to the fire&gas panel—meeting API RP 14C requirements without additional logic solvers.Over 18 months,the site reported zero missed alarms and a 40%reduction in maintenance call-outs due to early fault detection.Operators praised the optional local display for quick status checks during rounds—eliminating the need for handheld communicators in most cases.

Similarly,at a pharmaceutical plant in Germany,the HONEYWELL XNX-UTAV-RNIF1 monitors oxygen deficiency in nitrogen-purged storage rooms.Its SIL2 certification satisfied strict EU machinery directive requirements,while HART communication enabled remote verification during audits—demonstrating compliance without physical intervention.

Related Product Combination Solutions

HONEYWELL XNX-UTAV-RNIF2:Variant with enhanced surge protection for outdoor or lightning-prone areas

HONEYWELL XNX-HOUSING-ALM:Explosion-proof aluminum housing for Zone 1/Div 1 installations

HONEYWELL XNX-DISPLAY-KIT:Field-installable LCD display module for local readout

HONEYWELL XNX-PSU-24V:Dedicated 24 V DC power supply for non-loop-powered configurations

HONEYWELL Sensepoint XCD:Compatible point gas sensor family(toxic/combustible/O₂)

HONEYWELL XNX Configurator Software:PC-based tool for batch configuration,calibration logs,and diagnostics

HONEYWELL Safety Manager:Integrates HONEYWELL XNX-UTAV-RNIF1 relay signals into certified SIS logic

HONEYWELL Uniformance PHD:Historian that archives HART gas concentration trends for compliance reporting

Installation,Maintenance,and Full-Cycle Support

Installation of the HONEYWELL XNX-UTAV-RNIF1 is simplified by its modular design—sensor heads snap onto the transmitter base without tools,and terminal blocks accept stranded wires with screwless clamps.For hazardous areas,it mounts directly into certified XNX enclosures with pre-approved conduit entries,ensuring compliance with ATEX/IECEx installation rules.Loop-powered operation reduces wiring costs,while optional external power supports long cable runs.

Maintenance is minimized through smart features:automatic baseline correction,sensor lifetime tracking,and HART-enabled remote calibration.Technicians can verify performance or adjust span using a standard HART communicator—no need to open the enclosure in classified zones.All critical events(alarms,faults,calibrations)are time-stamped and stored for audit trails.

We provide comprehensive lifecycle support:from pre-sales sensor selection guidance,to on-site commissioning,cybersecurity documentation(for HART-over-IP gateways),and rapid exchange programs.Every HONEYWELL XNX-UTAV-RNIF1 we deliver is factory-tested for loop response,relay timing,and intrinsic safety parameters—and backed by a 12-month warranty with access to Honeywell-certified application engineers.

Contact us for a customized solution—whether you’re designing a new F&G system,upgrading legacy detectors,or ensuring compliance with OSHA PSM or Seveso III directives.

UFC921A101 3BHB024855R0101 UFC911B106 3BHE037864R0106 UDC920BE01 3BHE034863R0001 XVC770BE101 3BHE021083R0101 KUC755AE105 3BHB005243R0105 LXN1604-6 3BHL000986P7000 LWN2660-6E 3BHL000986P7002 UFC789AE 38HE014022P102 3BHL000734P0003 SLOV4.6/5.3 HIES308461R0012 HIES208441R.. ID8A92485001/022 3BHB009410R000 SG000247 3BHL000986P1006 XVC724BE101 3BHE009017R0102 DKTFM418B 3BHB015651P0001 PU180/63E 3BHB00916230001 HIES308461R0012 FPX86-9345–B 3BHL000986P0006 3BHL000734P0003 SLOV4.6/5.3 UFC921A101 3BHE024855R0101 PPC907BE101 3BHE024577R0101 XVC724BE101 3BHE009017R0102 IEC60129,62271-102 MI-CONP KUC755AE105 3BHB005243R0105 HIES308461R0012 MG160MD2-42FF300-F1 PTC 160℃ TP211 MG160MD2-42FF300-F1 ABB S-073N ALU 3BHB009884R5211 ABB S-093H 3BHB030478R0309 ABB S-123H 3BHB030479R0512 ABB UFC912A101 3BHE039426R0101 ABB 5SHY4045L0001 3BHB018162R0001 ABB S-113N 3BHB018008R0001 W4 KUC755AE105 3BHB005243R0105 HIEE401807R0001 3BHB046719R0008 STRAUB FLEX1L TB820V2 S-053M 3BHB012897R003 *12 3BHB014556R0001 3BHB010823R0002 CDP312R XVC768AE102 UFC789AE101 S-073N KU C755AE105 XVC770BE101 UFC760BE42 PPC907BE UFC760BE43 XVC769AE101 LDMTR-01 UAC389AE02 LTC391AE01 PPC905AE101 UAC383AE01 LDLPTR-01

Reviews

Reviews

There are no reviews yet.

Be the first to review “HONEYWELL XNX-UTAV-RNIF1 Advanced Toxic/Combustible Gas Transmitter – 4–20 mA + Relay + HART”

Your email address will not be published. Required fields are marked *

Post comment